[![Technical Safety BC colour logo with gear](https://blog.technicalsafetybc.ca/hs-fs/hubfs/TSBC_Stacked_RGB%20300%20dpi%20-%20transparent%20background-1.png?width=600&height=179&name=TSBC_Stacked_RGB%20300%20dpi%20-%20transparent%20background-1.png "Technical Safety BC colour logo with gear")](https://www.technicalsafetybc.ca/)

[Visit main site](https://www.technicalsafetybc.ca/) [Contact us](https://www.technicalsafetybc.ca/contact/contact-us)

[Back to blog](https://blog.technicalsafetybc.ca/)

# Food Trucks, Permits, and Gas Installation: All You Need to Know

 July 20, 2023

 3 Minute read

![](https://blog.technicalsafetybc.ca/hubfs/Imported_Blog_Media/Food%20Truck-2.jpg)

Did you know that gas appliance installations in BC’s food trucks and trailers must be done under a [gas installation permit](https://www.technicalsafetybc.ca/permits/gas-installation)?  A permit should be taken out for a food truck or trailer by a[ licensed gas contractor](https://www.technicalsafetybc.ca/find-contractor-archived), while food carts should have evidence of certification from an [accredited certification agency](https://www.technicalsafetybc.ca/alerts/directive-approved-certification-marks-gas-appliances) on it.

What’s the difference between food trucks and food carts?

- **Food trucks and trailers** have four walls and a roof. They don't fit into a standard so they require a gas installation permit and inspection by a gas safety officer. Once it passes the final on-site inspection, a Record of Installation Permit decal will be put on by the safety officer.  
   
- **Food carts **don’t have four walls and a roof. They fit within the scope of ANSI Z83.11-2016 CSA 1.8-2016 and must be certified by an accredited certification agency. A certification mark is used as evidence of certification.
  
  ![Thumbnail](https://blog.technicalsafetybc.ca/hs-fs/hubfs/Imported_Blog_Media/Food%20Truck-2.jpg?width=1100&height=745&name=Food%20Truck-2.jpg "Food truck")

The process to having a food truck or trailer approved includes:

- a licensed contractor taking out a [Commercial Installation permit](https://portal.technicalsafetybc.ca/forms/FRM0501) for the installation of the gas fuel system and appliances,
- a licensed contractor requests inspections at each stage of construction of the unit, and, once complete,
- a safety officer performs an assessment of the installation and, if it passes, the safety officer will place a decal on the vehicle.

The decal is valid for the life of the food truck or trailer as long as there are no changes to the gas system or appliances. If any changes are made, the decal is then void and a new permit process would be required to have a new decal applied to the unit.

Learn more:

- [Directive: Mobile outdoor food service unit gas approval requirements](https://www.technicalsafetybc.ca/regulatory-resources/regulatory-notices/directive-mobile-outdoor-food-service-unit-gas-approval-requirements)
- [Directive: Approved certification marks for gas appliances](https://www.technicalsafetybc.ca/regulatory-resources/regulatory-notices/directive-certification-and-approval-marks-gas-appliances-bc)

 

 

 Share this article: 

[![Share on Facebook](https://blog.technicalsafetybc.ca/hubfs/raw_assets/public/technical-safety-bc/images/facebook-blue.svg)](http://www.facebook.com/share.php?u=https%3A%2F%2Fblog.technicalsafetybc.ca%2Ffood-trucks-permits-and-gas-installation-all-you-need-know%3Futm_medium%3Dsocial%26utm_source%3Dfacebook) [![Share on LinkedIn](https://blog.technicalsafetybc.ca/hubfs/raw_assets/public/technical-safety-bc/images/linkedin-blue.svg)](http://www.linkedin.com/shareArticle?mini=true&url=https%3A%2F%2Fblog.technicalsafetybc.ca%2Ffood-trucks-permits-and-gas-installation-all-you-need-know%3Futm_medium%3Dsocial%26utm_source%3Dlinkedin) [![Share on Twitter](https://blog.technicalsafetybc.ca/hubfs/raw_assets/public/technical-safety-bc/images/twitter-blue.svg)](https://twitter.com/intent/tweet?original_referer=https%3A%2F%2Fblog.technicalsafetybc.ca%2Ffood-trucks-permits-and-gas-installation-all-you-need-know%3Futm_medium%3Dsocial%26utm_source%3Dtwitter&url=https%3A%2F%2Fblog.technicalsafetybc.ca%2Ffood-trucks-permits-and-gas-installation-all-you-need-know%3Futm_medium%3Dsocial%26utm_source%3Dtwitter&source=tweetbutton&text=Food%20trucks%2C%20permits%2C%20and%20gas%20installation) [![Share on Email](https://blog.technicalsafetybc.ca/hubfs/raw_assets/public/technical-safety-bc/images/email-blue.svg)](mailto:?subject=Check%20out%20https%3A%2F%2Fblog.technicalsafetybc.ca%2Ffood-trucks-permits-and-gas-installation-all-you-need-know%3Futm_medium%3Dsocial%26utm_source%3Demail%20&body=Check%20out%20https%3A%2F%2Fblog.technicalsafetybc.ca%2Ffood-trucks-permits-and-gas-installation-all-you-need-know%3Futm_medium%3Dsocial%26utm_source%3Demail)

## Subscribe for safety updates and insights

## Browse topics

- [Homeowner](https://blog.technicalsafetybc.ca/tag/homeowner)
- [Gas](https://blog.technicalsafetybc.ca/tag/gas)
- [Contractor](https://blog.technicalsafetybc.ca/tag/contractor)
- [Electrical](https://blog.technicalsafetybc.ca/tag/electrical)
- [Asset Owner](https://blog.technicalsafetybc.ca/tag/asset-owner)
- [Ask A Safety Officer](https://blog.technicalsafetybc.ca/tag/ask-a-safety-officer)
- [Homeowner Safety](https://blog.technicalsafetybc.ca/tag/homeowner-safety)
- [Passenger Ropeways](https://blog.technicalsafetybc.ca/tag/passenger-ropeways)
- [Boiler, PV and Refrigeration](https://blog.technicalsafetybc.ca/tag/boiler-pv-and-refrigeration)
- [Carbon Monoxide](https://blog.technicalsafetybc.ca/tag/carbon-monoxide)
- [Public Safety](https://blog.technicalsafetybc.ca/tag/public-safety)
- [Amusement Devices](https://blog.technicalsafetybc.ca/tag/amusement-devices)
- [Elevating Devices](https://blog.technicalsafetybc.ca/tag/elevating-devices)
- [Railways](https://blog.technicalsafetybc.ca/tag/railways)
- [Alternative Safety Approaches](https://blog.technicalsafetybc.ca/tag/alternative-safety-approaches)
- [CO Alarm](https://blog.technicalsafetybc.ca/tag/co-alarm)
- [Client Support](https://blog.technicalsafetybc.ca/tag/client-support)
- [Smarter Safety](https://blog.technicalsafetybc.ca/tag/smarter-safety)
- [FSR](https://blog.technicalsafetybc.ca/tag/fsr)
- [Camping](https://blog.technicalsafetybc.ca/tag/camping)
- [Chairlift](https://blog.technicalsafetybc.ca/tag/chairlift)
- [Corporate news](https://blog.technicalsafetybc.ca/tag/corporate-news)
- [RV safety](https://blog.technicalsafetybc.ca/tag/rv-safety)
- [Skiing](https://blog.technicalsafetybc.ca/tag/skiing)
- [Travel](https://blog.technicalsafetybc.ca/tag/travel)
- [Vacation](https://blog.technicalsafetybc.ca/tag/vacation)
- [extreme heat](https://blog.technicalsafetybc.ca/tag/extreme-heat)
- [snowboarding](https://blog.technicalsafetybc.ca/tag/snowboarding)

## Related articles

![](https://blog.technicalsafetybc.ca/hs-fs/hubfs/Imported_Blog_Media/Food%20Truck-2.jpg?width=352&name=Food%20Truck-2.jpg)

### Ask a Gas Safety Officer: What Inspection Stickers Are Affixed to Food Trucks Being Inspected for Gas Appliances?

 August 1, 2018

 4 Minute read

 Food trucks, trailers, and carts in BC must have the installation of any gas appliances performed under a gas installation permit obtained by a licensed gas contractor or have the appropriate certification. Find out more.

[Read More](https://blog.technicalsafetybc.ca/ask-gas-safety-officer-what-inspection-stickers-are-affixed-food-trucks-being-inspected-gas?hsLang=en)

![](https://blog.technicalsafetybc.ca/hs-fs/hubfs/Imported_Blog_Media/GasStove.jpg?width=352&name=GasStove.jpg)

### Ask an electrical safety officer: I'm installing a natural gas stove. Is an outside-vented range hood mandatory or can I use a recirculating range hood?

 March 5, 2019

 1 Minute read

 Unless the installation instructions of the new range specifically require an exhaust hood vented to the outdoors, there is no other code requirement under the Gas Safety Regulation which requires a hood for a residential range.

[Read More](https://blog.technicalsafetybc.ca/ask-electrical-safety-officer-im-installing-natural-gas-stove-outside-vented-range-hood?hsLang=en)

![](https://blog.technicalsafetybc.ca/hs-fs/hubfs/Imported_Blog_Media/Row%20of%20caravan%20trailers%20_0.jpg?width=352&name=Row%20of%20caravan%20trailers%20_0.jpg)

### Ask a gas safety officer: What type of permit is required for a mobile camp?

 December 12, 2018

 1 Minute read

 Mobile camps may consist of relocatable structures consisting of multiple certified mobile trailers/manufactured buildings which are not considered certified mobile homes. They are considered as a unit and require a commercial installation permit per unit.

[Read More](https://blog.technicalsafetybc.ca/blog/ask-gas-safety-officer-what-type-permit-required-mobile-camp?hsLang=en)

Back to top

[Report an incident](https://portal.technicalsafetybc.ca/report-incident/incident-reporting-form)

[Contact us](https://www.technicalsafetybc.ca/contact/contact-us)

As a province-wide organization, Technical Safety BC respectfully recognizes that its employees live and work on the traditional and unceded territories of the many Indigenous Nations that have thrived throughout British Columbia since time immemorial.

[© 2026 Technical Safety BC](https://www.technicalsafetybc.ca/)

- [Cookie Policy](https://www.technicalsafetybc.ca/cookie-policy)
- [Privacy Policy](https://www.technicalsafetybc.ca/privacy-policy)
- [Terms of Use](https://www.technicalsafetybc.ca/terms-use)

<https://www.instagram.com/technicalsafetybc/?hl=en>

<https://twitter.com/techsafetybc?lang=en>

<https://ca.linkedin.com/company/technical-safety-bc>

<https://www.facebook.com/technicalsafetyBC/>

```json
{
  "@context" : "https://schema.org",
  "@type" : "BlogPosting",
  "author" : {
    "@type" : "Person",
    "name" : "Technical Safety BC",
    "url" : "https://blog.technicalsafetybc.ca/author/technical-safety-bc"
  },
  "dateModified" : "2023-12-19T20:17:04.899Z",
  "datePublished" : "2023-07-20T07:00:00.000Z",
  "headline" : "Food trucks, permits, and gas installation",
  "image" : [ "https://blog.technicalsafetybc.ca/hubfs/Imported_Blog_Media/Food%20Truck-2.jpg" ],
  "mainEntityOfPage" : {
    "@id" : "https://blog.technicalsafetybc.ca/food-trucks-permits-and-gas-installation-all-you-need-know",
    "@type" : "WebPage"
  },
  "publisher" : {
    "@type" : "Organization",
    "logo" : {
      "@type" : "ImageObject",
      "url" : "https://blog.technicalsafetybc.ca/hubfs/TSBC_Stacked_RGB%20300%20dpi%20-%20transparent%20background-1.png"
    },
    "name" : "Technical Safety BC"
  }
}
```