Living in a remote community or off-grid home can mean relying on different types of heating, cooking, and power generation equipment. Propane appliances, generators, and other fuel-burning devices can all produce carbon monoxide (CO) if they aren't installed, operated, or maintained safely.

Whether you live in a remote community, cabin, or off-grid home, it's important to understand the risks and take steps to protect yourself and your household.

What is Carbon Monoxide?

Carbon monoxide is an odourless, tasteless, invisible gas produced when fuels like propane, natural gas, oil, wood, or charcoal burn incompletely.

CO poisoning is the most common unintentional poisoning in Canada. CO interferes with the body's ability to absorb oxygen, which can lead to serious illness, severe side effects, or death.

Preventing CO Poisoning in Remote and Off-Grid Homes

Choose Appliances Approved for Use in Canada

If you rely on propane or other fuel-burning appliances for heating, cooking, or hot water, it's important to make sure they're approved for use in Canada.

Appliances that don’t meet Canadian safety requirements may have unsafe combustion or ventilation systems, increasing the risk of malfunction and carbon monoxide exposure.

Before purchasing or installing an appliance, check that it has the appropriate Canadian certification or approval markings.

Be especially careful when purchasing equipment online or from outside Canada, as not all appliances sold internationally meet Canadian safety requirements.

Have Gas Appliances Installed and Serviced by a Licensed Contractor

Gas appliances must be installed by a licensed gas contractor to help ensure they're installed safely and meet applicable requirements.

Finding a licensed gas contractor can be more challenging in remote communities, but proper installation is essential. Incorrectly installed appliances or venting systems can allow carbon monoxide to build up indoors, putting everyone in the building at risk.

This includes propane-fired appliances commonly used in remote and off-grid homes, such as heaters, stoves, water heaters, and refrigerators.

Have existing gas appliances serviced annually or as recommended by the manufacturer. Regular maintenance can help identify problems with equipment, ventilation, and safe operation.

Keep Outdoor Appliances Outdoors

Generators, outdoor water heaters, barbecues, and other outdoor fuel-burning equipment can produce dangerous levels of carbon monoxide when used in enclosed spaces.

Always follow the manufacturer’s instructions and check whether an appliance is approved for indoor or outdoor use. Some outdoor water heaters may look similar to indoor models but are labelled for outdoor use only. Never operate outdoor-only appliances inside a home, garage, shed, enclosed porch, or other enclosed space. Even if a shower room or shed is detached from your main home, it’s still considered an enclosed space, not an outdoor location.

Generators should always be operated outdoors, well away from doors, windows, and air intakes. Opening a door or window does not make it safe to operate outdoor fuel-burning equipment indoors.

Install CO Alarms on Every Level of Your Home

A working CO alarm is essential, regardless of whether your home is connected to the electrical grid.

Install Canadian-certified CO alarms on every level of your home, with at least one alarm near sleeping areas. Consider installing an additional alarm in a mechanical or service room where fuel-burning appliances are located.

Test alarms monthly and replace them according to the manufacturer's instructions.

If your home relies on solar power, batteries, or a generator for electricity, consider how your CO alarms will continue operating during a power interruption. Choose alarms with a suitable power source or battery backup.

Prepare for Power Outages and Extreme Weather

Power outages, heavy snowfall, and cold temperatures can increase the risk of CO exposure, particularly when alternative heating or power sources are needed.

Before an emergency:

  • Make sure your heating appliances and generators are properly maintained.
  • Check that outdoor exhaust vents, chimneys, and air intakes are clear of snow, ice, and debris.
  • Never use outdoor barbecues, camping stoves, or portable outdoor heaters within your home or any enclosed space.
  • Make sure everyone in your household knows what to do if a CO alarm sounds.

What Should You Do if You Suspect Carbon Monoxide Exposure?

If your CO alarm sounds or you suspect carbon monoxide exposure:

  1. Leave the building immediately and move to fresh air.
  2. Call 911 from outside or another safe location.
  3. Do not re-enter until emergency responders confirm it's safe to do so.

If you live in a remote area where emergency services may take longer to arrive, it's especially important to have a plan for contacting emergency responders and getting everyone to a safe location. Learn more about the symptoms of CO exposure.

Carbon Monoxide Safety Starts With Prevention

Whether you live off-grid year-round or spend time at a remote cabin, using properly certified equipment, working with licensed gas contractors, and maintaining CO alarms can help reduce the risk of carbon monoxide exposure.

Taking a few precautions before the colder months or your next extended stay can help keep your household safe.

Learn more about CO safety.